- POST a QUESTION or COMMENT about labels & certification for manufactured homes, mobile homes, mobile home, caravan, static caravan or trailer or doublewide homes
If you are conducting a steam winterization, be sure to include photos of the boiler, the expansion tank, and the RPZ valve. Also provide photos of the sump pump if there is one. Winterization Stickers. Winterization stickers must be placed on the toilets, sinks, hot water tank, front door, or picture window. Dress up your planner with these beautiful free printable watercolor planner stickers, including inspirational quotes, to do lists, checklists, bunting flags, and more! Both a free printable image or free Silhouette Print & Cut file, to be used with a Silhouette CAMEO or Portrait, included.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
Data Tags & Labels on Double-Wides, Mobile Homes, Trailers or Manufactured Housing:
This article explains the requirement-for and data contents in labels or data tags found on mobile homes, trailers, doublewides, and other manufactured housing or cottages. We explain where to find the label or data tag on your home and how to de-code its contents.
This article series provides mobile home inspection, troubleshooting & repair procedures, defect lists, & references to standards. We explain where to look for costly or dangerous problems on mobile homes, trailers, or double-wides.
We also provide a MASTER INDEX to this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need.
Manufactured Home Labels & Mobile Home Labels & Manufactured Housing Labels & Certifications
The data tag shown here identifies a 1989 Supreme, a Park Model Trailer in the RV family produced by Northlander Industries, A Canadian company who has produced manufactured homes, cottages, RVs, and trailers since 1964. This tag is on a Canadian RV.
Contacting Northlander with the label's model number and serial number allowed the company to give us details about the construction of this trailer as we discussed with a reader at WINTERIZING the TRAILER below in this article.
At page top is an RPTIA industry sticker used for RV Park Trailers in the U.S. and observed on a trailer in an RV park in southern New Jersey.
[Click to enlarge any image]
Is it a 'Mobile Home' or a 'Manufactured Home' ?
The term “manufactured home” is the common term used in the industry to describe homes built after June 15, 1976 (the date national building standards were implemented by the Department of Housing and Urban Development (HUD).
The industry currently uses the term “mobile home” to describe homes built prior to implementation of the HUD standards. (U.S. EPA 2011)
Label Requirements for Manufactured Homes / Mobile Homes
For U.S. Manufactured homes, doublewides, trailers, and similar constructins, Sections 3280.5 Data Plate through 3280.11 of HUD Regulations for manufactured homes include language that describes the labeling requirements for this housing.
The following information must be provided for manufactured homes:
- Mobile Home INSTALLATION MANUAL - For new/recent mobile home, every manufacturer is required to provide instructions on site preparation, installation and anchoring.
- Mobile Home Manufacturer's CERTIFYING LABEL - on rear section outside or near the main entry door, HUD Insignia
- Mobile Home DATA PLATE - near the main electrical panel or other visible & accessible location (under sink for many manufactured homes): name of mfg., serial and HUD ID, zone information (see Structurediscussion).
A Certification Label must be permanently affixed to each transportable section of each manufactured home manufactured for sale in the United States. Other countries have similar regulations.
- Mobile Home DAMAGE DURING TRANSPORT: if the unit was damaged during transport it no longer conforms to the standards and should not beaccepted by the code official
HUD Regulations for Manufactured Home Labeling
§ 3280.5 [Manufactured home / mobile home] Data plate.
Each manufactured home shall bear a data plate affixed in a permanent man- ner near the main electrical panel or other readily accessible and visible location.
Each data plate shall be made of material what will receive typed information as well as preprinted information, and which can be cleaned of ordinary smudges or household dirt without removing information contained on the data plate; or the data plate shall be covered in a permanent manner with materials that will make it possible to clean the data plate of ordinary dirt and smudges without obscuring the in- formation.
Each data plate shall contain not less than the following information:
(a) The name and address of the manufacturing plant in which the manufac- tured home was manufactured.
(b) The serial number and model designation of the unit, and the date the unit was manufactured.
(c) The statement:
This manufactured home is designed to comply with the Federal Manufactured Home Construction and Safety Standards in force at the time of manufacture.
(d) A list of the certification label(s) number(s) that are affixed to each transportable manufactured section under § 3280.8.
(e) A list of major factory-installed equipment, including the manufactur- er’s name and the model designation of each appliance.
(f) Reference to the roof load zone and wind load zone for which the home is designed and duplicates of the maps as set forth in §3280.305(c). This information may be combined with the heating/cooling certificate and insulation zone map required by §§3280.510 and 3280.511.
The Wind Zone Map on the Data Plate shall also contain the statement:
This home has not been designed for the higher wind pressures and anchoring provi- sions required for ocean/coastal areas and should not be located within 1500′ of the coastline in Wind Zones II and III, unless the home and its anchoring and foundation system have been designed for the increased re- quirements specified for Exposure D in ANSI/ ASCE 7–88.
(g) The statement:
This home has—has not—(appropriate blank to be checked by manufacturer) been equipped with storm shutters or other pro- tective coverings for windows and exterior door openings.
For homes designed to be located in Wind Zones II and III, which have not been provided with shutters or equivalent covering devices, it is strongly rec- ommended that the home be made ready to be equipped with these devices in accordance with the method recommended in the manu- facturers printed instructions.
(h) The statement: ‘‘Design Approval by’’, followed by the name of the agency that approved the design.
[59 FR 2469, Jan. 14, 1994]
§ 3280.6 [Manufactured home / mobile home] Serial number.
(a) A manufactured home serial num- ber which will identify the manufac- turer and the state in which the manu- factured home is manufactured, must be stamped into the foremost cross member. Letters and numbers must be 3⁄8 inch minimum in height. Numbers must not be stamped into hitch assem- bly or drawbar.
§ 3280.7 Excluded structures.
Certain structures may be excluded from these Standards as modular homes under 24 CFR 3282.12.
[52 FR 4581, Feb. 12, 1987]
§ 3280.11 [Manufactured home / mobile home] Certification label.
(a) A permanent label shall be affixed to each transportable section of each manufactured home for sale or lease in the United States. This label shall be separate and distinct from the data plate which the manufacturer is required to provide under §3280.5 of the standards.
(b) The label shall be approximately 2 in. by 4 in. in size and shall be perma- nently attached to the manufactured home by means of 4 blind rivets, drive screws, or other means that render it difficult to remove without defacing it. It shall be etched on 0.32 in. thick aluminum plate.
The label number shall be etched or stamped with a 3 letter designation which identifies the production inspection primary inspection agency and which the Secretary shall assign. Each label shall be marked with a 6 digit number which the label supplier shall furnish. The labels shall be stamped with numbers sequentially.
(c) The [Manufactured home / mobile home] label shall read as follows:
As evidenced by this label No. ABC 000001, the manufacturer certifies to the best of the manufacturer’s knowledge and belief that this manufactured home has been inspected in accordance with the requirements of the Department of Housing and Urban Development and is constructed in conformance with the Federal manufactured home construction and safety standards in effect on the date of manufacture. See date plate.
(d) The label shall be located at the tail-light end of each transportable section of the manufactured home ap- proximately one foot up from the floor and one foot in from the road side, or as near that location on a permanent part of the exterior of the manufactured home unit as practicable.
The road side is the right side of the manufactured home when one views the manufactured home from the tow bar end of the manufactured home.
[42 FR 960, Jan. 4, 1977. Redesignated at 44 FR 20679, Apr. 6, 1979, as amended at 52 FR 47553, Dec. 15, 1987. Redesignated and amend- ed at 58 FR 55003, Oct. 25, 1993]
The above HUD regulation on manufactured home labeling is excerpted from Manufactured Home Construction and Safety Standards, Part 3280 as cited at MOBILE HOME CODES & STANDARDS
Winterizing an RV, Trailer - Label Gives Clues
Reader Question: is my 1989 Northlander a Seasonal or 'All Season' Trailer?
I have a 1989 Northlander 43x12 home. I need to know if it is a Seasonal or All Season trailer for insurance.
It was sold to me as an All Season to live in year round but too many say it is not. I can not have any insurance problems because of this. I have included a photo of the manufacturers plate.
I have seen other Northlander trailers were the model number ends with an S like mine means seasonal and AS means All Season. I saw on your page that disabled and fixed/low income there is no charge [for limited consulting for people of limited means or ability - Ed]
I am on WSIB (WCB) and CPPDIS for PTS and PCS since 1992. This is really causing me stress because I can not get an answer. I just need something that I can have to show what my home is so I can put this to rest.
Any help in identifying the type of trailer would be greatly appreciated. Even an email PDF showing the spects or something that I can print out or get in the mail. A hard copy. I just don't understand why there is no information on this?! Thank you in advance.
- Anon by private email 2017/03/21
[Click to enlarge any image]
Reply: The model on your trailer data tag indicates seasonal use
We contacted Northlander Industries (that information is given below) with the model number and serial number of your trailer to ask about the model and its specifications. In an example of superb customer service, we got a very useful response from Northlander: here's the information about your home:
The “S” at the end of the plan no. only refers to the model which was “Supreme” so it has nothing to do with the seasonality of the unit.
This Northlander unit was built with the following specifications:
- Insulation (All fiberglass batt)
- Floor: R-20 Walls and Ceiling: R-12
- 4 mil Poly vapour barrier on walls and ceiling
- 2”x4” walls, 2”x8” floor joists, Bow string roof truss
- Double slider aluminum windows (not a true thermopane)
- 4 panel aluminum patio door (not a true thermopane)
- Furnace: 36,000 BTUH forced air propane
- Water Heater: 10 gallon propane
This unit was built with reasonable insulation, windows, doors and the furnace is capable of heating during the winter months and providing the necessary level of comfort to the occupants.
The Supreme is a Park Model Trailer which clearly falls in the RV Family, it is not a residential home.
Now Anon, based on these specifications and on information provided by Northlander, in my OPINION a seller such as the person who sold the trailer to you should not have marketed it as a year round home - nor did Northlander Industries ever do so for the model we identify above.
However my undersdtanding is that there are Northlander Supreme’s with the same construction specifications that are occupied year round.
Winterizing Advice for Your Northlander Supreme Park Model Trailer
I follow with some advice about winterizing your particular trailer.
Northlander has been in business for a long time, since 1964 but the only 'owners manual' the company currently provides online
- NORTHLANDER PARK MODEL OWNER'S MANUAL [PDF], (April 2013) Northlander Industries, 165 Thames Road East, Hwy. 83, Exeter, Ontario, Canada N0M 1S3, retrieved 2017/03/21, original source: http://northlanderindustries.com/wp-content/uploads/2014/01/Product-Manual-April-22-2013.pdf and is for a recent model.
The manual above is for a newer model (2013) than your Park Model trailer - those instructions include a warning about attempting to use the home in winter (search the PDF for 'season') as they expect the water heater to be drained to protect from freezing.
Keep in mind that it's highly likley that Northlander has made product changes between your 1989 model and the 2013 Northlander Park models described in the manual they provide above.
Watch out: The text which I will excerpt below is to me a red flag warning and suggests that the company may also have experience with the use of their seasonal-use park model trailers in freezing conditions:
The unit you have purchased from your dealer may not be intended for 12 month, continuous or sub-zero winter occupancy. The purchaser has sole responsibility and discretion to ensure safe winter use. The plumbing drainage, water supply system and park connections (if available during off season use) must be kept from freezing.
You'll want to review the possible freeze points and take care to address them.
Watch out: injudicious use of heat tapes or heaters can in turn be a fire hazard as we explain in our pipe freeze protection article listed below
Generally, keeping heat on and fixing drafts and insulating are what make an otherwise perhaps marginal structure able to survive through freezing weather. But if the home isn't intended for winter occupancy that means there is indeed risk of freezing if its plumbing and water heater aren't drained.
If your concern is principally risk of damage from freezing, you'll want to look at some of the freezeproofing articles at InspectApedia.com including those I list below.
You'll also want your heating system inspected and serviced to be sure it's reliable before cold weather arrives.
- HEAT SOURCES to AVOID FROZEN PIPES - that may be particularly important for your Northlander
- PIPE FREEZE PROTECTION - home
- WINTERIZE A BUILDING - topic home, giving an overall strategy
- WINTERIZE - HEAT ON PROCEDURE - things that might let you set the thermostat down without catastrophe
- Northlander offers some winterizing advice for their units at WINTERIZING your UNIT - http://northlanderindustries.com/winterizing-your-unit/
Readers will find at that link additional links to Northlander's Plumbing System, a Storage and Winterization checklist, a general maintenance guideline checklist, and an owner's manual
Home Insurance including for water or freezing damage
I'm told that the S/AS distinction you've heard of indicating Seasonal or 'All Seasonal' is be correct. Rather the 'S' is desribed by Northlander as a suffix to the plan number and indicates the model 'Supreme'.
It would make sense to me, as you say you want to avoid any insurance issue, to ask your insurance agent for advice about how to insure the home. You can indicate that you intend to occupy the home all year round - if that's the case, and want it insured appropriately.
Or you can accept insurance for a 'seasonal use' building and then you will be responsible for losses that occur if the home is used during winter.
Contact Northlander Industries
- Northlander Industries, 165 Thames Road East, Hwy. 83, Exeter, Ontario, Canada N0M 1S3, Tel: 519-235-1530, Website: http://northlanderindustries.com
Guide to Demolition & Removal of a Manufatured Home, Mobile Home or Trailer
This discussion has moved to MOBILE HOME DEMOLITION / REMOVAL
...
Continue reading at MOBILE HOME CODES & STANDARDS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see MOBILE / MANUFACTURED HOME LABEL FAQs - questions & answers originally posted to this article
Or see these
Recommended Articles
- MOBILE HOMES, DOUBLEWIDES, TRAILERS - home
- MODULAR HOME or OFFICE LABELS & CODE COMPLIANCE - using a modular or mobile home label to prove code compliance
Suggested citation for this web page
MOBILE / MANUFACTURED HOME LABELS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
INDEX to RELATED ARTICLES: ARTICLE INDEX to MANUFACTURED & MOBILE HOMES
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
...
Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed:if your comment contains an image, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Technical Reviewers & References
- [1] Section 184 Indian Home Loan Guarantee Program, U.S. Department of Housing & Urban Development, web search 1/5/2012, original source: portal.hud.gov/hudportal/HUD?src=/program_offices/public_indian_housing/ih/homeownership/184 - Quoting:
The Section 184 Indian Home Loan Guarantee Program is a home mortgage specifically designed for American Indian and Alaska Native families, Alaska Villages, Tribes, or Tribally Designated Housing Entities. Section 184 loans can be used, both on and off native lands, for new construction, rehabilitation, purchase of an existing home, or refinance.
Also see Freddie Mac & Fannie Mae - [2] Native American Housing Loan Guarantee Program HUD Section 184 Loans At A Glance, FannieMae, web search 1/5/12, original source: efanniemae.com/sf/mortgageproducts/pdf/section184aag.pdf
- [5] 'Modular Home Construction, special defects and inspection methods' Dan Friedman, NY Metro ASHI Seminar, Holiday Inn, Crowne Plaza, White Plains NY, October 4, 1996
- [9] New York State: 'Manufactured Homes: an installation guide for the code enforcement official,' undated. [Div. of Code Enforcement & Admin. - 518-474-4073, George E. Clark, Jr., Director] - this is a guide tool, not an enforcement code or standard.
- [10] HUD State Administrative Agency (for 36 states) (NY: 518-474-4073) - for complaints
- [11] Manufactured Housing Institute, 2101 Wilson Blvd. Ste. 610, Arlington VA 22201 703-558-0400 www.mfghome.org
- [12] NYMHA, 35 Commerce Ave., Albany NY 12206-2015 518-435-9859 800-721-HOME (they want the Star Program to provide for separate assessment of manufactured homes)
- [13] Consumer Reports: www.consumerreports.org - special report 2/98
- [14] Mobile Home Inspection Checklist, Florida, Town of Lady Lake Building Department
- [15] Thanks to home inspector Peter Bennett for eagle-eye editing assistance regarding spelling at this web article series. Little Silver, NJ 07739 Office 732-758-9887 Fax 732-758-8993 Cell 732-245-9817 afullhouseinspectionco@gmail.com
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
- Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
- ...
- Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. The firm provides professional HOME INSPECTION SERVICES and also extensive HOME INSPECTION EDUCATION and home inspection-related PUBLICATIONS. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The Home Reference Book & illustrations from The Illustrated Home. Carson Dunlop Associates' provides extensive home inspection education and report writing material.
The ILLUSTRATED HOME illustrates construction details and building components, a reference for owners & inspectors.
Special Offer: For a 5% discount on any number of copies of the Illustrated Home purchased as a single order Enter INSPECTAILL in the order payment page 'Promo/Redemption' space.
TECHNICAL REFERENCE GUIDE to manufacturer's model and serial number information for heating and cooling equipment, useful for determining the age of heating boilers, furnaces, water heaters is provided by Carson Dunlop Weldon & Associates
Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on any number of copies of the Technical Reference Guide purchased as a single order. Just enter INSPECTATRG in the order payment page 'Promo/Redemption' space. - The HOME REFERENCE BOOK - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume.
Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page 'Promo/Redemption' space. InspectAPedia.com editor Daniel Friedman is a contributing author.
Or choose the The HOME REFERENCE eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones.
Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page 'Promo/Redemption' space. - Building inspection education & report writing systems from Carson, Dunlop & Associates Ltd
COMMERCIAL BUILDING INSPECTION COURSES - protocol ASTM Standard E 2018-08 for Property Condition Assessments
HOME INSPECTION EDUCATION COURESES (Canada)
HOME INSPECTION EDUCATION COURSES (USA) including home study & live classes at eleven colleges & universities.
HOME INSPECTION EDUCATION: HOME STUDY COURSES - ASHI@Home Training 10-course program.
Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on these courses: Enter INSPECTAHITP in the order payment page 'Promo/Redemption' space. InspectAPedia.com editor Daniel Friedman is a contributing author. - The Horizon Software System manages business operations,scheduling, & inspection report writing using Carson Dunlop's knowledge base & color images. The Horizon system runs on always-available cloud-based software for office computers, laptops, tablets, iPad, Android, & other smartphones
Property Preservation Winterization Overview
As a property preservation contractor, you will face many challenges. The biggest of these are winterization and de-winterization. It isn’t particularly tough work; however, it does have to be performed according to a strict protocol and newbies to the business will find themselves on a steep learning curve.
It’s important to get winterization and dewinterization activities right for one main reason: if you don’t, you may be liable for any expenses that are incurred as a result of improper maintenance.
There are two types of winterizations, dry and wet. Dry Heat systems are forced hot air, they will have furnaces, vents and/ or registers. Wet heat systems can either be “Steam Heat” or “Radiant Heat”. “Steam Heat” will have a steam boiler and steam running through the system, generally radiators. “Radiant Heat” will have a hot water boiler, expansion tank, and hot water running through radiators or copper tubing located in the floor, walls, and sometimes ceilings. Radiant heat may also be referred to as a “wet system” or “hot water baseboard heat.”
HERE’S WHAT YOU WILL FIND ON THIS PAGE
- Property Preservation Winterization Overview
- Materials and Tools Needed To Complete Property Preservation Winterizations
- Winterization Season Start and End Dates Schedule
- FHA Winterization Cost Schedule
- Documenting the Winterization
- Summary of How I Complete a Property Preservation Winterization Order
- How to Handle Frozen Properties
- Winterization Videos
- Tips For Winterizing a Home With Radiant or Steam Heat (also known as Wet Winterization)
- De-Winterizing a Property
- FHA Attachment Regarding Winterization Requirements and Cost Schedule
Materials and Tools Needed To Complete Property Preservation Winterizations
- Zip ties to secure shut-off valves at water meters
- Generator and extension cords
- Air compressor with operating gauge
- Air compressor hose fittings to connect your air compressor to spickot or the faucet located at the washing machine sink
- Shop Vac to drain water from toilet bowls and sinks
- Pink “non-toxic” antifreeze, sometimes called RV antifreeze
- Your client’s custom winterization sticker notices
- Clear winterization film to place over sinks and toilets
- Plunger
- Basic cleaning supplies
Winterization Season Start and End Dates Schedule
FHA Winterization Cost Schedule
Documenting the Winterization
You should always remember that you are liable for issues with your property preservation services, and winterization liability is at the top of the list.
Take the time to create a checklist for each procedure you perform for each client. So in terms of winterization, if you work for three different clients, you will have three different checklists – one for each. As you go through the checklist, modify it when you notice something is new or has changed. The in-house company policies and procedures manual (that you created yourself) should dictate that you keep master copies of each checklist. You should also keep a record of any changes and the date that they were made.
I appreciate that this is a lot of work, but it will be difficult to recall every step of every procedure for every property and for every client. See what I mean? It’s already sounding like a big job.
Don’t underestimate the need for iron-clad documentation. The day will come when you have to prove or disprove an allegation against you, so it is really important to keep more records for yourself than you ever submit to your clients.
Remember, the checklists included in this guide are only a starting point. Use them as a
template to create your own which you can revise and update as needed.
Winterization Photos
Photo documentation is critical, and you will be required to back up all winterization work with high quality photos. You will not be paid for work performed if it is not fully photo documented, and there are no exceptions.
It is your responsibility to submit before, during, and after photos of all work done. These photos will be used to justify any bids you are submitting and to document the property’s condition.
All photos must be right side up, and most companies prefer them to be landscape rather than portrait. Photos that are distorted, fuzzy, too light, too dark, or unclear in any way will usually be deleted by the company’s QC department. If you are lucky, they will request replacements, but if you’re not, they might just cancel the payment to you and send another contractor to do the job. It is very common for monies to be withheld because of inadequate photos.
Do not send duplicates of photos. Specific photo requirements are often included on the work order, but if they are not, take time to find out your client’s individual requirements.
Take photos of all capped water lines; the cleaning of the toilets; the addition of antifreeze to all taps, fixtures, and appliances; the disconnecting of the water meter; the draining of the hot water tank; the zip-tie on the cut-off water meter if required by your client; and the blowing of the lines with the gauge visible.
All photos should be taken from the same angle and include a visible point of reference.
If you are conducting a steam winterization, be sure to include photos of the boiler, the expansion tank, and the RPZ valve. Also provide photos of the sump pump if there is one.
Winterization Stickers
Winterization stickers must be placed on the toilets, sinks, hot water tank, front door, or
picture window. Make sure that they are clearly visible in all winterization after-photos.
How To Complete a Property Preservation Winterization
STEP 1: Disconnect the Water Supply – You must attempt to locate the main water shut-off at the curb and make sure the shut-off valve is in the OFF position. Take 2-3 photos showing this process. Next you will locate the water meter and the main interior shut-off valve. Turn the main shut-off valve into the OFF position, disconnect the water meter and then connect a “zip tie” to the main water shut-off valve and finish by installing a 3/4″ black pipe “plug”.
STEP 2: Draining the System – Starting in the basement, make sure all gas line shut-off valves are in the OFF position throughout the entire property. Next you will connect a small garden hose to the water heater and then place the other end of the hose either into a floor drain or outside and proceed to drain all water from the water heater. If the property uses well water, you will drain all holding tanks and disconnect the electric to the well pump. Lastly, you will drain all the toilet tanks and toilet bowls.
Note(s): You can either use a siphon pump to drain the toilet bowl or you can use a small shop-vac. My crew has a small shop-vac that is used specifically for this purpose. Secondly, if you find feces in the toilet either you can clean it out or figure out a way to give your client a bid to replace a damaged toilet. Always remove a nasty toilet by having your helper disconnect it and place it into a large plastic commercial-grade garbage bag or two BEFORE CARRYING IT OUTSIDE.
STEP 3: Preparing To Blow Out Plumbing Pipes – Start at the main shut-off valve located near the water meter by connecting your pressure tester. Then follow the plumbing supply pipes throughout the entire property with the goal of making sure that all mid-line shut-off valves are in the OPEN position and all faucets are in the closed position. The few exceptions are as follows: all toilets that have a “fixture shut-off valve” need the valve to be in the CLOSED POSITION.
STEP 4: Pressure Testing the System – Turn your air compressor on and set the pressure at 35 PSI. Do not exceed 40 PSI as you may cause damage. Once the pressure builds up, take 2-3 photos showing your air compressor connected and another 2-3 photos showing the pressure gauge. Now you must once again follow the pipes while listening for a high pitched “whistling” noise, which would indicate breaks in the plumbing pipes. If any leaks are found, mark them by putting a piece of duct tape approximately 6″ away. Once you have marked all of them, proceed to take 2-3 photos of each damaged section of pipe. Make sure to take good quality pictures since those will be the only proof your client will have. Lastly, you must leave the air compressor connected for a minimum of 30 minutes.
Note(s): A good way I have found to prove that you actually completed an entire pressure test is by holding a cell phone near the pressure gauge and taking 1-2 pictures at the beginning and 1-2 pictures after 30 minutes. If there are no breaks, then your client will clearly be able to verify that you followed protocol because the gauge will show the needle in exactly the same position in both pictures. This method has saved me from chargebacks a few times when a plumbing leak showed up after I completed my pressure test.
STEP 5: Blowing All Remaining Water Out Of Plumbing Supply Pipes – Next, you will start at the laundry sink and turn the faucet into the ON position and you should immediately see a small amount of water flying out. Keep your camera handy because you will need to take 2-3 photos showing this water shooting out and 1-2 photos once the water stops. Repeat this process at ALL OTHER FAUCETS that will be located in each kitchen and each bathroom. And don’t forget to take photos at each faucet, even if there no more water coming out. Your client will still want to see that you completed all of the steps and believe me when I say this: in your client’s mind, if you don’t have a photo of something then you didn’t do it. They will NEVER accept anyone telling them, “you can trust me”, in lieu of photos.
STEP 6: Add Antifreeze To Plumbing Drains – You need to pour antifreeze into all toilet bowls and tanks, all kitchen & bathroom sink traps, shower and tub traps, floor drains, and dishwasher drains. Take 1-2 pictures “during” each pour and also 2-3 photos showing each sink and toilet “before” and “after”.
Note(s): A typical single family with 1 kitchen and 1.5 bathrooms should take approximately 2 gallons of antifreeze.
STEP 7: Posting Stickers and Notices – Winterization notification stickers are applied to toilets, showers, tubs, water heater, water meter, dishwasher, and all sinks. Additionally, toilet wrap is installed on all toilets to further ensure they are not used. Notices are posted at the entryways of the home advising anyone entering that the property has been winterized and warning against the use of any plumbing fixtures.
FINAL NOTES: If a property has radiant or steam heat, you have several additional steps to complete. In addition to the preceding steps, you must also drain the boiler unit and expansion tank, loosen all of the bleeder pins on each radiator, complete a pressure test to all the plumbing pipes throughout this heating system and lastly, apply a winterization sticker to the boiler.
Your client will most likely have specific instructions for these types of winterizations.
How to Handle Frozen Properties
Do not attempt to undertake any winterization work if you find the property already frozen. Call your client to clarify their procedures for frozen properties and ask them for instructions.
If your work order does include instructions on how to proceed with frozen properties, follow these instructions closely. Some servicing companies have funds set aside for emergencies such as thawing the property, but others may require a bid to do this.
Make notes and take lots of photographs. Call the servicing company, and jot down the time and details of the call. A bid must be submitted for all damages, and all damages must be reported. Some companies require this report and the photos on the day that the damage is discovered.
If you are bidding to thaw a property, the bid must include at the very least:
- The number and types of devices to be used such as heaters and torches
- The number of people involved in the process and the approximate number of man hours
- A bid for pressure testing after thawing is complete
- A bid for winterization after thawing is complete
Winterization Videos
Identifying Various Types of Heating Systems
How To Complete Winterizations
How To Complete a Property Preservation Winterization Work Order: 4 Part Video Series
How To Winterize a Pool
How To Install a Safety Pool Cover
How To Winterize An In-Ground Sprinkler System
Tips For Winterizing a Home With Radiant or Steam Heat (also known as Wet Winterization)
- Drain the boiler and all heating loops. Repair, replace, or install (as necessary to comply with state health department requirements) a Reduced Pressure Zone (RPZ) valve.
- Fill the boiler and all heating loops with a non-toxic antifreeze (propylene-glycol) solution tested to a freeze point of 40 degrees Fahrenheit or lower. Flush all lines and bleed all vents.
- Return the heating system to normal operating temperature and pressure. Check the entire system for proper operation. Leave the heat on and set the thermostat to 55 degrees.
- Tape the furnace electrical switch to the “on”position. Tape a card above the switch stating, “Do Not Remove Tape. Do Not Turn Off”.
How to De-Winterize a Property
De-winterizing a property is the opposite of winterizing it. De-winterizing will allow you to make the plumbing system useable again so it can be checked for leaks before it is used by the occupants.
To de-winterize, simply follow these steps, taking a photo of each:
- Remove and dispose of winterization notices, warnings, and stickers
- Conduct a pressure test to ensure the system can still hold 35 psi for 30 minutes
- Close all spigots, faucets, water lines, and valves
- Reconnect the water meter
- Prepare faucets for water flow by removing the aerators. This will allow debris to drain from the system
- Reconnect appliances such as refrigerators, washing machines, dishwashers, and water heaters to the water supply
- Open water supply valves to turn on water, then check for leaks
- Fill hot water tank with water
- Turn on heating system
- Connect electric or gas to hot water tank
- Make sure heating system is working properly and set thermostat to 55 degrees
- Wait for heating system to go through a full cycle to make sure it will work unattended
- Run water through all faucets and spigots to flush antifreeze
- Bleed air from plumbing system by letting the faucets and spigots burp
- Flush toilets
- Check again for leaks
- Never leave a property with leaking plumbing or without heat
FHA Attachment Regarding Winterization Requirements and Cost Schedule
As with everything, the HUD have developed a set of guidelines that outline how utilities and properties should be maintained during the winter to prevent frost damage. These guidelines also contain information about wells and sump pumps.
I. Winterization of utilities
Unless the variations section of the chart below specifies otherwise, all utilities should be turned off. In some states, heat should remain on. If this is the case, the heat should be maintained at 55 degrees Fahrenheit unless specified otherwise.
Condominiums and attached dwellings:
If a condo or attached dwelling is part of a Planned Unit Development (PUD), the water services and utilities should remain on throughout the winter. If the property uses a community water service, contact the realtor or asset manager for information as to how to maintain water services. The same applies for shared electrical services.
Equipment damage:
If you fail to complete your responsibilities according to the winterization guidelines, you may be held accountable for any damage to the plumbing and heating systems that arise.
Sump pumps:
In properties in which a sump pump is installed to keep basements and other lower-ground areas dry, the electricity should be left on to allow the sump pump to operate, even if the property is located in a state in which the electricity should be turned off. Ensure that you check the sump pump is fully operational as part of your maintenance services. If the existing sump pump is broken, or you believe there is a requirement to have one installed, you will need pre-written approval if the cost of installing the sump pump exceeds $250.
Utility Accounts
Utility accounts including electricity, gas, home heating oil and water, should be in the Mortgagee’s name until conveyance of the property to HUD. The Mortgagee should pay the bill and may claim reimbursement for utility costs covering the period from the date of vacancy until the end of the billing cycle that includes the date of conveyance. Payment of a utility bill that includes charges for a portion of a billing cycle that is post conveyance is the exception to HUD’s policy on non-reimbursement of expenses after the conveyance date. It is the Mortgagee’s responsibility to notify the utility company that ownership of the security property has been transferred to HUD (to the attention of the M&M contractor), upon conveyance. A copy of the notice should be maintained in the claim review file.
In states where utilities should remain on, if there is any reason to believe that a Mortgagor may abandon a property, the Mortgagee should contact the utility company to request that the Mortgagee be notified of non-payment of utilities so that utilities can be transferred to the Mortgagee’s name and the heat remain on if the Mortgagor vacates.
Propane and oil systems:
If propane or oil heating systems are in use, put in place a “keep full” contract with the supplier in properties that require the heat to be on at all times.
II. Water
Domestic water:
Unless an ongoing water supply is required, the local water supply company should be contacted, the water supply should be shut off, and a final meter reading should be arranged. No waterlines or meters should be removed because this may incur a fee from the water utility company. In the event that a water meter needs to be installed, the permissible expenditure is up to $350 for an electric heater or $420 for a gas heater. These pre-approved limits include the cost of installation.
Wells:
If the property’s water is supplied by a private well, this should be switched off at the breaker panel, the breaker should be taped off, and the water supply line between the pressure tank and the property should be disconnected. The pressure tank itself should be fully drained. If it is surface mounted, the pump housing should be drained. If it is submersible, the valve should be disconnected, and all pump, suction, and piping equipment should be fully drained. A hose bib should also be installed on the pressure tank side of the breaker and tagged “For Water Testing.” Any additional fixtures should also be winterized.
Reduced Pressure Zone Device (RPZ or RPZD):
Some properties may have an RPZ installed. The purpose of this is to prevent backflow and protect the water supply from being contaminated. If the property has an RPZ in place, contact the local authority for specific instructions as to the regulations pertaining to the installation and use of these devices. If there is a requirement to install or replace an RPZ, you will need to get pre-written approval from the RPZ if the cost of doing so will exceed $70.
III. Winterization
If you are operating in a jurisdiction in which winterization is required, you will need to winterize the property between October 1st and Match 31st. There are some exceptions to these time periods and these can be found in the section on “Local Variation from General Requirements.” Winterization should be possible in one visit and should be performed once a year. In the event that the property does need to be rewinterized for some reason, you will need to obtain prior approval. Winterization should include all of the following:
- Cleaning the toilets and draining all plumbing, heating systems or any other areas of the property that contain water that can potentially freeze and cause damage.
- If you need to use air pressure to clean out the system, this is acceptable, as too is the use of antifreeze. However, only use these measures if you believe they are imperative to preventing water from freezing and causing damage.
- Check the regulations and legal requirements that are in force in the area in which you operate and ensure that you perform winterization activities in accordance with these.
- Take “before” and “after” photographs to document the process. Make sure you date each image and include the address of the property at which it was taken.
Dry Heat Systems:
Drain all hot water heaters and piping to prevent frozen water from causing damage. Ensure that you keep valves and faucets open throughout the process and that you close them once the draining process is complete. Place a suitable amount of antifreeze in all fixtures and in tanks and cisterns.
Wet Heat, Radiant, Hydronic or Hot Water Baseboard Systems:
Complete the draining and preventative measures as per those used for dry heat systems. Make sure all radiators are open throughout the process and do not remove any bleeder pins from the radiators. All pipes that supply the radiators should be drained and an air compressor should be used to fill them with air. Place a suitable amount of antifreeze in all radiator pipes.
Steam Heat Systems:
Complete the draining and preventative measures as per those used for dry heat systems. Be careful to verify whether the heating system is hot water or steam heated in advance. A telltale sign is that steam heat systems will incorporate valves at the bottom of the radiator. All pipes that supply the radiators should be drained and an air compressor should be used to fill them with air. Place a suitable amount of antifreeze in all radiator pipes. If you think there may be a problem with the heating system, report this to the AMC. As part of the winterization process, you should check that the system is working and that there are no leaks. To do this, use an air compressor to pressurize the system to 53 pounds and inspect for leaks. The general rule of thumb is that the system should be capable of holding the air pressure without leakage for at least 30 minutes.
IV. Repair Bids
The Mortgagee may spend up to $250.00, for required repairs or installation of any new equipment required to maintain utilities or properly winterize a property including but not limited to, water wells, water meters, heating equipment, etc. Where such repairs will exceed $250, the mortgagee shall obtain two independent competitive bids and submit the bids to the appropriate M&M contractor for approval. Please advise the M&M where the meter may only be removed by the utility company.
LOCAL VARIATIONS FROM GENERAL REQUIREMENTS
ATLANTA Homeownership Center
Illinois/Indiana
Winterize year round, regardless of the month the property is secured. However, heat will remain in shut down mode. Utilities are to remain off unless required to operate a sump pump.
Caribbean
Do not winterize.
Florida
The water supply should be shut off at the curb. Notify utility companies to cancel all services. Do not drain the water heater or water lines. Do not winterize.
Jacksonville Florida ONLY
Winterize from September 1 through April 30 from Jacksonville north to the Georgia line. However, heat will remain in shut down mode. Utilities are to remain off unless required to operate a sump pump.
DENVER Homeownership Center
Colorado
Winterization is required from September 1 through April 30. Heat is to remain on in condominiums and town-homes.
Kansas, Missouri, Oklahoma
Winterization is required from September 1 through April 30. However, heat system will remain in shut down mode. Utilities are to remain off unless required to operate a sump pump.
Minnesota, Montana, Iowa, North Dakota, Wyoming
Winterization is required from September 1 through April 30. Utilities and heat are to remain on.
Wisconsin
Winterization is required from September 1 through April 30. Turn water off at meter in house ONLY. Heating system will remain in shut down mode. Utilities are to remain off unless required to operate a sump pump.
SANTA ANA Homeownership Center
Turn water off at the street after winterization in all Santa Ana M&M contract areas, except Alaska.
Alaska
All properties should be winterized year round. Heat should be left on with the thermostat set at 55 degrees Fahrenheit. Properties should be conveyed with water, gas, and utilities ON. Propane and fuel oil delivery services should remain on automatic fill. Utilities should remain in the servicing Mortgagee’s name until conveyance. The servicing Mortgagee is instructed and authorized to switch utilities into HUD’s name effective on the date of conveyance.
Water service may be turned off at the street (key box) only if the property has a forced air or electric heating system and the domestic water system has been properly winterized.
Arizona/California
Winterize properties above 2,000 feet only. However, heat system will remain in shut down mode. Utilities are to remain off unless required to operate a sump pump.
Hawaii/Pacific Islands
Do not winterize.
Nfr Winterization Sticker Template Sticker
Nevada
No winterization except for Pahrump zip code 89041 and Mt. Charleston zip code 89124. All other winterization is completed on a case‑by‑case basis. However, heat system will remain in shut down mode. Utilities are to remain off unless required to operate a sump pump.
Nfr Winterization Sticker Template Printable
Reno, Nevada
Winterize from September 15 through April 15. However, heat system will remain in shut down mode. Utilities are to remain off unless required to operate a sump pump.
Oregon
Winterize from November 1 through March 31 only. However, heat system will remain in shut down mode. Utilities are to remain off unless required to operate a sump pump.
Nfr Winterization Sticker Template Checklist
Washington
Winterize from September 15 through April 15. However, heat system will remain in shut down mode. Utilities are to remain off unless required to operate a sump pump.